ABC-CA18-SMNM-1.0M
|
Manufacturer: AtlanTecRF
Manufacturer Part No: ABC-CA18-SMNM-1.0M
|
- Frequency DC-26.5GHz (subject to connector type)
- For Test and System Applications
- Velocity of Propagation 70%
- Polyurethane Jacket - Blue
- Ultra Flexible
- Phase Stability +/-2 degrees
- Cost Effective
- Stock Availability
- RoHS Compliant
AtlanTecRF's ABC series of coaxial cable assemblies are designed for general purpose laboratory and equipment applications where flexibility, performance and affordability are key features. With a solid silver plated copper clad inner conductor and PTFE dielectric the outer conductor consists of three layers. The inner layer is silver plated copper tape followed by an interlayer of aluminium tape below the outer layer of silver plated copper braid.
The jacket over this is high flexibility polyurethane and at each connector there is a three level polyolefin strain relief.
Connectors have passivated stainless steel bodies in either SMA or Type N male. Standard STOCK lengths range from 0.3 to 5.0 metres but custom configurations of both cable length and connector type are also available to order.
General Specifications |
Operating Frequency |
DC-26.5GHz (SMA); DC-18GHz (Type N) |
Impedance: | 50 ohms |
Velocity of Propagation |
70% |
Phase Stability |
+/-2 degrees with flexure |
Insertion Loss |
0.8dB/ft. (2.6dB/m) max. @ 18GHz |
VSWR |
Refer to table below for Return Loss |
Capacitance |
98pF/m (29.8pF/ft) |
Insulation Resistance |
5000M ohms min. |
Dielectric Withstand Voltage |
1000V RMS |
Shielding Effectiveness |
90dB min. |
Temperature Range |
-30 to +105C |
Preferred Bending Radius |
120mm |
Connector Retention Force |
100N min. |
Recommended Mating Torque |
0.8Nm - 1.1Nm |
Centre Conductor |
Silver Plated Copper Clad Steel Wire |
Cable Dielectric |
Solid PTFE |
Inner Shield |
Silver Plated Copper Tape |
Middle Shield |
Aluminium Tape |
Outer Shield |
Silver Plated Copper Braid |
Cable Jacket |
Polyurethane - Blue |
Cable Diameter |
5.3mm |
Marking Sleeve |
Polyolefin |
Strain Relief Tube |
Bonding Black Shrink Tube - 3 level |
Connector Interface |
MIL-STD-348 |
Connector | Body |
Stainless Steel, Passivated |
| Centre Contact |
Beryllium Copper, Gold Plated |
| Coupling Nut |
Stainless Steel, Passivated |
Standard Assembly Lengths |
0.3 to 5.0m +/-1% (in 0.5m increments) |
Typical Performance Data @ 25C
Part Number | Connectors | Length (Metres) | Return Loss (dB) min. | Insertion Loss (dB) typ. |
2GHz | 4GHz | 8GHz | 12GHz | 18GHz | 2GHz | 4GHz | 8GHz | 12GHz | 18GHz |
ABC-CA18-SMSM-0.3M |
SMA Male/SMA Male |
0.3m |
28 |
26 |
23 |
20 |
18 |
0.4 |
0.5 |
0.6 |
0.8 |
1.0 |
ABC-CA18-SMSM-0.5M |
SMA Male/SMA Male |
0.5m |
28 |
26 |
23 |
20 |
18 |
0.5 |
0.6 |
0.8 |
1.0 |
1.4 |
ABC-CA18-SMSM-1.0M |
SMA Male/SMA Male |
1.0m |
28 |
26 |
23 |
20 |
18 |
0.7 |
1.1 |
1.5 |
1.9 |
2.6 |
ABC-CA18-SMSM-1.5M |
SMA Male/SMA Male |
1.5m |
28 |
26 |
23 |
20 |
18 |
1.1 |
1.7 |
2.3 |
2.9 |
3.9 |
ABC-CA18-SMSM-2.0M |
SMA Male/SMA Male |
2.0m |
28 |
26 |
23 |
20 |
18 |
1.4 |
2.2 |
3.0 |
3.8 |
5.2 |
ABC-CA18-SMSM-2.5M |
SMA Male/SMA Male |
2.5m |
28 |
26 |
23 |
20 |
18 |
1.8 |
2.8 |
3.8 |
4.8 |
6.5 |
ABC-CA18-SMSM-3.0M |
SMA Male/SMA Male |
3.0m |
28 |
26 |
23 |
20 |
18 |
2.1 |
3.3 |
4.5 |
5.7 |
7.8 |
ABC-CA18-SMSM-3.5M |
SMA Male/SMA Male |
3.5m |
28 |
26 |
23 |
20 |
18 |
2.5 |
3.9 |
5.3 |
6.7 |
9.1 |
ABC-CA18-SMSM-4.0M |
SMA Male/SMA Male |
4.0m |
28 |
26 |
23 |
20 |
18 |
2.8 |
4.4 |
6.0 |
7.6 |
10.4 |
ABC-CA18-SMSM-4.0M |
SMA Male/SMA Male |
4.5m |
28 |
26 |
23 |
20 |
18 |
3.2 |
5.0 |
6.8 |
8.6 |
11.7 |
ABC-CA18-SMSM-5.0M |
SMA Male/SMA Male |
5.0m |
28 |
26 |
23 |
20 |
18 |
3.5 |
5.5 |
7.5 |
9.5 |
13.0 |
ABC-CA18-SMNM-0.3M |
SMA Male/N Male |
0.3m |
28 |
26 |
23 |
20 |
18 |
0.4 |
0.5 |
0.6 |
0.8 |
1.0 |
ABC-CA18-SMNM-0.5M |
SMA Male/N Male |
0.5m |
28 |
26 |
23 |
20 |
18 |
0.5 |
0.6 |
0.8 |
1.0 |
1.4 |
ABC-CA18-SMNM-1.0M |
SMA Male/N Male |
1.0m |
28 |
26 |
23 |
20 |
18 |
0.7 |
1.1 |
1.5 |
1.9 |
2.6 |
ABC-CA18-SMNM-1.5M |
SMA Male/N Male |
1.5m |
28 |
26 |
23 |
20 |
18 |
1.1 |
1.7 |
2.3 |
2.9 |
3.9 |
ABC-CA18-SMNM-2.0M |
SMA Male/N Male |
2.0m |
28 |
26 |
23 |
20 |
18 |
1.4 |
2.2 |
3.0 |
3.8 |
5.2 |
ABC-CA18-SMNM-2.5M |
SMA Male/N Male |
2.5m |
28 |
26 |
23 |
20 |
18 |
1.8 |
2.8 |
3.8 |
4.8 |
6.5 |
ABC-CA18-SMNM-3.0M |
SMA Male/N Male |
3.0m |
28 |
26 |
23 |
20 |
18 |
2.1 |
3.3 |
4.5 |
5.7 |
7.8 |
ABC-CA18-SMNM-3.5M |
SMA Male/N Male |
3.5m |
28 |
26 |
23 |
20 |
18 |
2.5 |
3.9 |
5.3 |
6.7 |
9.1 |
ABC-CA18-SMNM-4.0M |
SMA Male/N Male |
4.0m |
28 |
26 |
23 |
20 |
18 |
2.8 |
4.4 |
6.0 |
7.6 |
10.4 |
ABC-CA18-SMNM-4.5M |
SMA Male/N Male |
4.5m |
28 |
26 |
23 |
20 |
18 |
3.2 |
5.0 |
6.8 |
8.6 |
11.7 |
ABC-CA18-SMNM-5.0M |
SMA Male/N Male |
5.0m |
28 |
26 |
23 |
20 |
18 |
3.5 |
5.5 |
7.5 |
9.5 |
13.0 |
ABC-CA18-NMNM-0.3M |
N Male/N Male |
0.3m |
28 |
26 |
23 |
20 |
18 |
0.4 |
0.5 |
0.6 |
0.8 |
1.0 |
ABC-CA18-NMNM-0.5M |
N Male/N Male |
0.5m |
28 |
26 |
23 |
20 |
18 |
0.5 |
0.6 |
0.8 |
1.0 |
1.4 |
ABC-CA18-NMNM-1.0M |
N Male/N Male |
1.0m |
28 |
26 |
23 |
20 |
18 |
0.7 |
1.1 |
1.5 |
1.9 |
2.6 |
ABC-CA18-NMNM-1.5M |
N Male/N Male |
1.5m |
28 |
26 |
23 |
20 |
18 |
1.1 |
1.7 |
2.3 |
2.9 |
3.9 |
ABC-CA18-NMNM-2.0M |
N Male/N Male |
2.0m |
28 |
26 |
23 |
20 |
18 |
1.4 |
2.2 |
3.0 |
3.8 |
5.2 |
ABC-CA18-NMNM-2.5M |
N Male/N Male |
2.5m |
28 |
26 |
23 |
20 |
18 |
1.8 |
2.8 |
3.8 |
4.8 |
6.5 |
ABC-CA18-NMNM-3.0M |
N Male/N Male |
3.0m |
28 |
26 |
23 |
20 |
18 |
2.1 |
3.3 |
4.5 |
5.7 |
7.8 |
ABC-CA18-NMNM-3.5M |
N Male/N Male |
3.5m |
28 |
26 |
23 |
20 |
18 |
2.5 |
3.9 |
5.3 |
6.7 |
9.1 |
ABC-CA18-NMNM-4.0M |
N Male/N Male |
4.0m |
28 |
26 |
23 |
20 |
18 |
2.8 |
4.4 |
6.0 |
7.6 |
10.4 |
ABC-CA18-NMNM-4.5M |
N Male/N Male |
4.5m |
28 |
26 |
23 |
20 |
18 |
3.2 |
5.0 |
6.8 |
8.6 |
11.7 |
ABC-CA18-NMNM-5.0M |
N Male/N Male |
5.0m |
28 |
26 |
23 |
20 |
18 |
3.5 |
5.5 |
7.5 |
9.5 |
13.0 |
Custom lengths, connector configurations and detailed cable specifications available on request
Power Handling at 25C (Watts) max. | Frequency (GHz) |
250 |
2 |
180 |
4 |
120 |
8 |
100 |
12 |
80 |
18 |
We reserve the right to change standard product specifications without notice but will be pleased to consider control drawings for quotation.
|
|
|